TOLERANCES
1010 ELECTRIC WELDED TUBING
WALL/in Thousands of an Inch (1= .001)
COLD ROLLED ROUND
 

 

Outside Diameter
3/8 thru 7/8 Over 1-7/8 thru 3-3/4 Over 3-3/4 thru 5 Over 5 thru 8
Ga. In. + + + +
22 .028 1 5 1 5        
20 .035 2 5 1 5        
18 .049 3 6 2 6        
16 .065 5 7 4 7 4 7 4 7
14 .083 6 7 5 7 4 7 4 8
13 .095 6 7 5 7 4 7 4 8
12 .109     6 8 5 8 5 9
11 .120     7 8 5 8 5 9
10 .134     7 8 5 8 5 9

 

TOLERANCES
1010 ELECTRIC WELDED TUBING
WALL/in Thousands of an Inch (1= .001)
HOT ROLLED ROUND
  Outside Diameter
3/4

thru 1

Over 1 thru 1-15/16 Over 1-15/16 thru 3-3/4 Over 3-3/4 thru 4-1/2 Over 4-1/2 thru 8
Ga. In. + + + + +
16 .065 5 9 4 10 3 11 2 12 2 12
15 .072 5 9 4 10 3 11 2 12 2 12
14 .083 6 10 5 11 4 12 3 13 3 13
13 .095 6 10 5 11 4 12 3 13 3 13
12 .109 6 10 5 11 4 12 3 13 3 13
11 .120 6 10 5 11 4 12 3 13 3 13
10 .134 6 10 5 11 4 12 3 13 3 13
9 .148     6 12 5 13 4 14 4 14
8 .165     6 12 5 13 4 14 4 14
7 .180     6 12 5 13 4 14 4 14
6 .203         7 15 6 16 5 17
5 .220         7 15 6 16 5 17
4 .238         12 20 11 21 10 22
3 .259         13 21 12 22 11 23

 

  TOLERANCES
  1010 ELECTRIC WELDED TUBING
WALL/in Thousands of an Inch (1= .001)
OUTSIDE DIAMETER
Cold Rolled Round Hot Rolled Round
OD, Inches Wall Inches Plus & Minus Inches OD, Inches       Plus & Minus Inches
Over Incl. Over Incl. Wall Inches
.374 5/8 .211 .003 .624 1-1/8 .065 .134 .0035
        1-1/8 2 .065 .259 .005
5/8 1-1/8 .211 .0035 2 2-1/2 .065 .259 .006
        2-1/2 3 .065 .259 .008
1-1/8 2 .211 .005     .284 .320 .010
        3 3-1/2 .065 .259 .009
2 2-1/2 .211 .006     .284 .360 .012
        3-1/2 4 .065 .259 .010
2-1/2 3 .211 .008     .284 .500 .015
        4 6 .065 .500 .020
3 3-1/2 .211 .009 6 8 .120 .500 .025
        8 9 .059 .125 .030
3-1/2 4 .211 .010 9 10 .105 .188 .035
                   
4 6 .211 .020            
                   
6 8 .211 .025